100 x 140 x 19′ Commercial Metal Building

100 x 140 x 19′ SS Metal Building Retail Building

April 29, 2012

Ship: $123,111 plus tax.
Firm Price for 30 days from post.
Within 200 Miles of Manufacturer

Additional Components:

SEALED PLANS FOR PERMIT INCLUDED
MASONRY WIND BEAM AND PARAPET FRAMING INCLUDED
BACK SIDE METAL WALL SHEETING INCLUDED
Gutters and Downspouts INCLUDED
12″ SIMPLE SAVER Reinforced Roof and 4″ Wall Insulation INCLUDED
4 Man doors 3×7 with panic bar INCLUDED
STEEL ERECTION LABOR BY OTHERS ADD $46,000
QTE# 12-112

Wright Building Systems, Inc. to provide metal building pricing as shown:

1. Building package provided, based on standard design practices, details, and materials. Any discrepancies between Plans and Specifications, this Quotation will govern. Standard materials, sizes, and deflections used per code unless noted.
2. Not including any liner panel, Energy Code requirements, special testing/inspections, finish paint on structure, windows, curbs, special clearances, FM rated “system”, bonds, labor, taxes, erection.
3. PRICING FIRM 14 days. Approval jobs must be returned for fabrication within 14 days, To hold current pricing, normal delivery must be allowed. Wright will not participate in liquidated damages clause. Delivery must be by June 1 to hold price. Retainage not allowed.

Job Specific Notes:

SHIPPING/DRAWINGS: freight allowed to site CTL KY , Letter of Certification, and Sealed engineering drawings, for metal building only, will be provided
BUILDING LOADS: 20# frame with reduction allowed, 90mph wind exposure B, 15# ground snow, 3# coll. load, occupancy factor I, Is/Iw/Ie = 1.0. H/240 SIDESWAY FOR GLASS

BRACING: SPECIAL PORTAL FRAMES AND HALF LOAD ENDWALLS
PANELS: ROOF: STD STANDING SEAM UL90 ZINC ALUM GALVALUME FINISH, 26 GA , Manufacturers leak warranty not provided/required.
WALLS: standard screw down PBR, 26 ga KYNAR 500 PAINT color,
SPACINGS: 28-0 O.C., 20-0 O.C. ENDS
ACCESSORIES/TRIM: Insulation SIMPLE SAVER THERMO SAVER

Design Disclosures:
Soil Profile
Jobsite soil properties meeting the requirements of a Stiff Soil Profile have been assumed in the determination of Seismic design values. If you have questions concerning the particular conditions at your jobsite, this information should be verified by your Foundation Engineer or local Building Permit authority.

Enclosure
You have ordered this building to be designed as an enclosed structure. This means that all exterior components, including those not supplied by the manufacturer, MUST be designed for full wind load. This will require the installation of walk doors, roll-up and overhead doors, and windows rated to the wind expressed on the metal building drawings. Furthermore, these items must be installed in strict accordance with the manufacturer’s instructions.

It is also possible that exterior components of the building, such as all doors and windows, must be constructed using projectile resistant materials. Consult your local building department for more information. Failure to comply with these requirements may create a situation endangering the lives of the inhabitants, or resulting in property damage. THE MANUFACTURER OF THE METAL BUILDING SYSTEM CANNOT BE HELD RESPONSIBLE FOR THIS IN ANY WAY.