50 x 80 x 18 Retail, Church, or Recreational Building

50x80x18 Retail, Church, or Recreational Building

METAL BUILDING KIT MATERIAL PRICE
Ship: $31,900 plus tax.
Firm Price for 30 days from post.
Within 200 Miles of Manufacturer
Qte 12-122

Additional Components:

3070 man door included
6070 windloaded man door with panic included
special bracing at sides included
Gutters/ Downspouts included
Sealed Plans and Design included
H.S. Window 3030-I (3ft X 3ft) Self Flashing included
H.S. Window 6030-I (6ft X 3ft) Self Flashing included

ALT ADD:
REINFORCED iNSULATION 4″ FOR ROOF AND WALLS
ADD $ 3,980 plus tax

Details:

3-Week Shipping Note: By selecting “3 week shipping” Buyer agrees to accept delivery of the Metal Building Systems immediately upon arrival at the location designated in the PO.Buyer’s Agreement. Failure to accept delivery will result in Buyer incurring storage fees as determined by Seller. Buyer agrees the “3 week shipping” option is subject to and strictly conditioned upon Seller’s Uniform Terms and Conditions (next page).

Building Sketch:

Important Note: Sketch is for representation of bay spacing, canopies and large framed openings only. Refer to your final anchor rod plan for actual dimensions.

Building Pricing Summary: Save Quote
QuoteID:
268205
Date:
4/20/2012
Customer PO:
Printable Version
Customer Number:
42636
Fab Status:
PRODUCTION Req Ship Date:

Account/Billing Information:
WRIGHT BUILDING SYSTEMS
JIM WRIGHT

HENDERSONVILLE, TN 37077
Email: JW@WRIGHTBUILDING.COM
Phone: (615) 822-4811 Fax: (615) 822-8771

Alternate Contact Information:

Project Name:

Shipping Information:
CAPE MAY, NJ 08204
County:Cape May

End User Information:
Engineering Design Info:
Building Type: Gabled Building
Width: 50′ Length: 80′ Height: 18′ Slope: 1:12
Sidewall Bay Config: 3 bays at 26 ft 8 in
Left Endwall: Half-load Non-expandable Frame Right Endwall: Non-expandable Bearing Frame
LEW Column Spacing: 15 / 20 / 15 REW Column Spacing: 15 / 20 / 15
LEW Girt: Flush REW Girt: Flush FSW Girt: Bypass BSW Girt: Bypass
Column Shape: Tapered
Code: NJBC 2007 Wind Load: 112 Exposure: C
Live Load: 20 Reducible: Yes Ground Snow: 20 Roof Snow: 14
Seismic: Ss = 0.147 S1 = 0.046 Seismic Coefficient: 0.24 Collateral Load: 0.5
Snow Factors: Is = 1.0 Ct = 1.0 Ce = 1.0
Occupancy = Normal Thermal Conditions = Normally Heated/All Others
Snow Exposure = All Other Roof/Terrain Conditions
Roof Dead Load = 2 psf
Building Colors:
Wall: Polar White (26 Gauge PBR) Roof: Galvalume Plus (26 Gauge PBR)
Eave Trim: Polar White
Downspout: Polar White Corner Trim: Polar White Jamb/Header Trim: Polar White
Doors & Factory Located Framed Opening Summary:
—-No Framed Opening Selected—-
Building Accessories:
Description
Selected
Price
Gutters and Downspouts
Yes
$699.37
Framed Opening Jamb Flashing
No
$0.00
Base Closures
No
$0.00
Standard Base Angle
$0.00
Roof Extensions:
—-No Roof Extensions Selected—-
Liner Panel:
—-No Liner Panel Selected—-
Other Accessories:
Description

Qty
Color
Price
H.S. Window
*3030-I (3ft X 3ft)
1
Bronze
$160.71
Option: Self-Flashing Window(s)
$0.00
H.S. Window
*6030-I (6ft X 3ft)
1
Bronze
$223.01
Option: Self-Flashing Window(s)
$0.00
Doors Type M3070 (Windloaded)
(3ft X 7ft)
1
White
$536.23
Swing Option:Left Handed
Option:Insulated Option Standard
$0.00
Lock Option:Standard Duty Lever Handle Lock
$37.11
Doors Type M6070 (Windloaded)
(6ft X 7ft)
1
White
$1,073.56
Swing Option:Left Handed
Option:Insulated Option Standard
$0.00
Lock Option:2 Leaves Active
2 Anti-Panic Hardware Surface Mounts
2 Lever Lock sets
6070 Removable Mullion
$569.16
Walkdoor Keyed Option: Doors are not keyed alike.
Misc Framed Openings:
—-No Misc Framed Openings Selected—–
Insulation:
—-No Insulation Selected—–
Wall Fastener Type: Standard Length: 1 1/4″
$0.00
Roof Fastener Type: Long Life Length: 1 1/4″
$0.00
Total Price Summary:
Base Building Price:
$24,521.30
Building Freight: (Caryville)
$2,481.50
Total Accessories Price (including fasteners, accessories):
$3,299.15
Not Stamped Overnight Service
$50.00
Tax:
To Be Added
Total Price (FOB seller’s facility with freight allowed):
$31,900.00 plus tax bp3uslv
Estimated Weight:
23404 lbs
TERMS OF PAYMENT: With payment to be made in Houston, Harris County, Texas, in accordance with terms to be established by the seller’s Credit Department.
Notes:

Foundation: Anchor bolts by others
Unless otherwise noted, the following specifications and conditions apply:
All paneling incorporates the purlin-bearing profile
Price includes long-life roof fasteners (lifetime red-rust warranty)
The pre-punched connecting clips for the structural elements, including endwall columns, are welded in place and then primed during fabrication
Buildings are engineered to meet listed codes and loads with the specified factory-located framed openings (size, location, and materials taken into account)
All structural elements for the specified framed openings (girts, jambs, and headers) are pre-cut and pre-punched and the necessary clips are welded on during fabrication
Whenever possible, paneling is pre-cut to accommodate the specified factory-located openings (some panels may require cutting in the field)

Design Disclosures:
Soil Profile
Jobsite soil properties meeting the requirements of a Stiff Soil Profile have been assumed in the determination of Seismic design values. If you have questions concerning the particular conditions at your jobsite, this information should be verified by your Foundation Engineer or local Building Permit authority.

Enclosure
You have ordered this building to be designed as an enclosed structure. This means that all exterior components, including those not supplied by the manufacturer, MUST be designed for full wind load. This will require the installation of walk doors, roll-up and overhead doors, and windows rated to the wind expressed on the metal building drawings. Furthermore, these items must be installed in strict accordance with the manufacturer’s instructions.

It is also possible that exterior components of the building, such as all doors and windows, must be constructed using projectile resistant materials. Consult your local building department for more information. Failure to comply with these requirements may create a situation endangering the lives of the inhabitants, or resulting in property damage. THE MANUFACTURER OF THE METAL BUILDING SYSTEM CANNOT BE HELD RESPONSIBLE FOR THIS IN ANY WAY.

This quote is still current. The price is subject to change at anytime without notice. To lock this price buy now.
www.www.austinwright.com or call 615-822-4811

check out the new website and Facebook page, Like us !!

Leave a Reply