Special 40x60x10 Metal Building

$ 18603 + tax for building, 2 man doors w/ p/cl, gut/ d spouts, insulation, freight ( 150 miles max)
see detail of costs below.

labor is $ 9700 by mm, separate contract

3-Week Shipping Note: By selecting “3 week shipping” Buyer agrees to accept delivery of the Metal Building Systems immediately upon arrival at the location designated in the PO.Buyer’s Agreement. Failure to accept delivery will result in Buyer incurring storage fees as determined by Seller. Buyer agrees the “3 week shipping” option is subject to and strictly conditioned upon Seller’s Uniform Terms and Conditions (next page).
Building Sketch:

Important Note: Sketch is for representation of bay spacing, canopies and large framed openings only. Refer to your final anchor rod plan for actual dimensions.

Building Pricing Summary:
Fab Status:
PRODUCTION Req Ship Date:

Account/Billing Information:
WRIGHT BUILDING SYSTEMS
JIM WRIGHT

HENDERSONVILLE, TN 37077
Email: JW@WRIGHTBUILDING.COM
Phone: (615) 822-4811 Fax: (615) 822-8771

Alternate Contact Information:

Project Name:

Shipping Information:
CHATTANOOGA, TN 37406
County:Hamilton

End User Information:
Engineering Design Info:
Building Type: Gabled Building
Width: 40′ Length: 60′ Height: 10′ Slope: 2:12
Sidewall Bay Config: 2 bays at 30 ft
Left Endwall: Non-expandable Bearing Frame Right Endwall: Non-expandable Bearing Frame
LEW Column Spacing: 20 / 20 REW Column Spacing: 20 / 20
LEW Girt: Flush REW Girt: Flush FSW Girt: Bypass BSW Girt: Bypass
Column Shape: Straight
Code: IBC 2009 Wind Load: 90 Exposure: B
Live Load: 20 Reducible: Yes Ground Snow: 14 Roof Snow: 11
Seismic: Ss = 0.455 S1 = 0.115 Seismic Coefficient: 0.65 Collateral Load: 1
Snow Factors: Is = 1.0 Ct = 1.0 Ce = 1.0
Occupancy = Normal Thermal Conditions = Normally Heated/All Others
Snow Exposure = All Other Roof/Terrain Conditions
Roof Dead Load = 2 psf
Building Colors:
Wall: Polar White (26 Gauge PBR) Roof: Polar White (26 Gauge PBR)
Eave Trim: Polar White
Downspout: Polar White Corner Trim: Polar White Jamb/Header Trim: Polar White
Doors & Factory Located Framed Opening Summary:
—-No Framed Opening Selected—-
Building Accessories:
Description
Selected
Price
Gutters and Downspouts
Yes
$465.09
Framed Opening Jamb Flashing
No
$0.00
Base Closures
No
$0.00
Standard Base Angle
$0.00
Roof Extensions:
—-No Roof Extensions Selected—-
Liner Panel:
—-No Liner Panel Selected—-
Other Accessories:
Description

Qty
Color
Price
Doors Type M3070 (Windloaded)
(3ft X 7ft)
2
White
$1,072.45
Swing Option:Left Handed
Option:Insulated Option Standard
$0.00
Lock Option:Lever Antipanic Hardware
$923.59
Operator: 1 Door Closer
$108.68
Walkdoor Keyed Option: Doors are not keyed alike.
Misc Framed Openings:
—-No Misc Framed Openings Selected—–
Insulation:
Description
Thickness
Location
Sq Feet
Price
White Polypropylene (WMP-VR-R)
3″
Walls
2636
$879.98
White Polypropylene (WMP-VR-R)
3″
Roof
2704
$902.03
Includes double sided tape and 1 roll(s) of patch tape.

Wall Fastener Type: Standard Length: 1 1/4″
$0.00
Roof Fastener Type: Long Life Length: 1 1/4″
$0.00
Total Price Summary:
Base Building Price:
$12,877.84
Building Freight: (Caryville)
$900.00
Total Accessories Price (including fasteners, accessories):
$2,569.81
Insulation Price:
$1,782.01
Insulation Freight:
$350.00
Stamped without Design Calculations Overnight Service
$125.00
Tax:
To Be Added
Total Price (FOB seller’s facility with freight allowed):c3vebp
$18,604.66
Estimated Weight:
10848 lbs
TERMS OF PAYMENT: With payment to be made in Houston, Harris County, Texas, in accordance with terms to be established by the seller’s Credit Department.
Notes:

Foundation: Anchor bolts by others
Unless otherwise noted, the following specifications and conditions apply:
All paneling incorporates the purlin-bearing profile
Price includes long-life roof fasteners (lifetime red-rust warranty)
The pre-punched connecting clips for the structural elements, including endwall columns, are welded in place and then primed during fabrication
Buildings are engineered to meet listed codes and loads with the specified factory-located framed openings (size, location, and materials taken into account)
All structural elements for the specified framed openings (girts, jambs, and headers) are pre-cut and pre-punched and the necessary clips are welded on during fabrication
Whenever possible, paneling is pre-cut to accommodate the specified factory-located openings (some panels may require cutting in the field)

Design Disclosures:
Soil Profile
Jobsite soil properties meeting the requirements of a Stiff Soil Profile have been assumed in the determination of Seismic design values. If you have questions concerning the particular conditions at your jobsite, this information should be verified by your Foundation Engineer or local Building Permit authority.

Enclosure
You have ordered this building to be designed as an enclosed structure. This means that all exterior components, including those not supplied by the manufacturer, MUST be designed for full wind load. This will require the installation of walk doors, roll-up and overhead doors, and windows rated to the wind expressed on the metal building drawings. Furthermore, these items must be installed in strict accordance with the manufacturer’s instructions.

It is also possible that exterior components of the building, such as all doors and windows, must be constructed using projectile resistant materials. Consult your local building department for more information. Failure to comply with these requirements may create a situation endangering the lives of the inhabitants, or resulting in property damage. THE MANUFACTURER OF THE METAL BUILDING SYSTEM CANNOT BE HELD RESPONSIBLE FOR THIS IN ANY WAY.

This quote is still current. The price is subject to change at anytime without notice. To lock this price buy now.

Note: If a price increase occurs, this quote will need to be re-priced. Frim 14 days, re vechrch212ptch3cbp121012

Leave a Reply